Product Application
New energy passenger vehicle motor rotor magnetization and meter magnetization detection equipment
This device is suitable for various sizes New energy passenger vehicles motor rotor The magnetization Magnetic testing (surface magnetic flux density) 。
Adopting the overall post magnetization method, it is safe and efficient, and the magnetic flux detection coil can be embedded inside the magnetization coil.
System Composition
Including magnetizing equipment, magnetizing power supply, magnetizing coil, chiller, magnetic flux meter (optional), magnetic detection software, Gaussian meter
Product Features
1. Wide compatibility range of rotor
2. Simple operation, high automation length, and anti misoperation capabilities
3. Magnetic detection software processes and analyzes data, and the detection data can be uploaded
4. Can detect whether the magnetization is saturated, whether the magnetic steel is missing insertion, and whether the polarity is correct
5. Easy to change models + Replacement car (optional)
6. The assembly line passes through the equipment, and the incoming material method of the assembly line tray
7. The magnetizing detection coil can be raised and lowered to communicate with the magnetizing power supply, and monitor the equipment status in real time
8. Can embed magnetic flux detection and magnetization + Integrated magnetic flux
Technical Specifications
project | Technical Specifications | Remarks |
input power | AC220V±5% 50/60Hz | |
input current | < 20A | |
rated power | < 5KW | |
Equipment noise | ≤ 75dB | Excluding instant magnetization |
Device dimensions | Approximately length, width, and height: 1800*1300*3000mm | Including electrical cabinet |
Equipment weight | ≤ 2000kg | |
changeover time | ≤ 30min | workwear + coil |
Usage environment
one | Ambient temperature 0℃~40℃; |
two | ambient humidity < 80% (no condensation allowed); |
three | Factory height (column top height): 3.5m; |
four | Ground load:> 2 tons/square meter; |
five | Size of transportation door for factory equipment: width 1500 x 2500mm high; |
six | Gas source: Air pressure 0.4~0.6Mpa , Flow rate of 0.3m 3/ min; |
seven | No dust, no oil fumes, no salt, no dripping water; |
eight | Avoid direct sunlight exposure ; |
nine | No flammable or corrosive liquids or gases; |
ten | No impact or high-frequency vibration; |
eleven | Usage location: Workshop open environment. |