1. Low power consumption, high efficiency, stable discharge waveform, and capable of long-term continuous operation;
2. The system adopts automatic control mode and provides reserved ports for easy upgrading and renovation;
3. Provide multiple protections and alarm outputs to ensure system safety;
4. Easy to operate, with precise touch screen monitoring;
5. The magnetizing voltage is adjustable from DC 200V to 2500V;
6. Automatically release capacitor power when shutting down, cutting off power, or experiencing faults;
| Project | PC-2520TP | PC-2530TP | PC-2540TP | PC-2550TP | Remarks |
Input power | AC220V±10% 50Hz single-phase two-wire | AC380V ±10% 50Hz two-phase three wire | |||
Input current | Max 40A | Max 55A | Max 60A | ||
Rated power | Max 10KVA | Max 18KVA | Max 20KVA | ||
Charging voltage | 200-2500VDC ± 0.2% @ full range The repeatability error is ± 1V@200 ~2500VDC | ||||
Output current | Max 30KA | ||||
Capacity | 2000uF | 3000uF | 4000uF | 5000uF | |
Max output energy | 6250J | 9375J | 12500J | 12625J | |
Charge and discharge time | < 4S | < 6S | < 8S | < 10S | |
Communication interface | RS-485/Ethernet | ||||
Weight | About 250KG | About 320KG | About 350KG | About 380KG | |
The width, depth, and height are approximately (mm) | 670*600*1525 | 900*800*1700 | |||
Serial Number | Usage Environment |
1 | Environmental temperature: 0 ℃~40 ℃; |
2 | Environmental humidity<80% (no condensation allowed); |
3 | Factory height (column top height): 2.5m; |
4 | Ground load:>1 ton/㎡; |
5 | Dimensions of the transportation door for factory equipment: width 1500 x height 2000mm; |
6 | No dust, no oil fumes, no salt, no dripping water; |
7 | Avoid direct sunlight exposure; |
8 | No flammable or corrosive liquids or gases; |
9 | No impact or high-frequency vibration; |
10 | Location of use: Workshop open environment. |