Including magnetizing equipment, magnetizer, magnetizing coil, chiller, magnetic flux meter (optional), magnetic detection software, Gaussmeter
1. Wide compatibility range of rotor
2. Simple operation, high automation length, and anti misoperation capabilities
3. Magnetic detection software processes and analyzes data, and the detection data can be uploaded
4. Can detect whether the magnetization is saturated, whether the magnetic steel is missing insertion, and whether the polarity is correct
5. Easy to change models + Replacement car (optional)
6. The assembly line passes through the equipment, and the incoming material method of the assembly line tray
7. The magnetizing detection coil can be raised and lowered to communicate with the magnetizing power supply, and monitor the equipment status in real time
8. Can embed magnetic flux detection and magnetization + Integrated magnetic flux
Project | Technical Specifications | Remarks |
input power | AC220V±5% 50/60Hz | |
input current | < 20A | |
rated power | < 5KW | |
Equipment noise | ≤ 75dB | Excluding instant magnetization |
Device dimensions | Approximately 1800 * 1300 * 3000mm in length, width, and height | Including electrical cabinet |
Equipment weight | < 2000kg | |
changeover time | ≤ 30min | Tooling+Coil |
1 | Environmental temperature: 0 ℃~40 ℃; |
2 | Environmental humidity<80% (no condensation allowed); |
3 | Factory height (column top height): 3.5m; |
4 | Ground load:>2 tons/square meter; |
5 | Dimensions of the transportation door for factory equipment: width 1500 x height 2500mm; |
6 | Gas source: pressure 0.4-0.6Mpa, flow rate 0.3m3/ min; |
7 | No dust, no oil fumes, no salt, no dripping water; |
8 | Avoid direct sunlight exposure; |
9 | No flammable or corrosive liquids or gases; |
10 | No impact or high-frequency vibration; |
11 | Location of use: Workshop open environment. |
Loading → Coil Descending → Magnetizing → Coil Resetting → Transferring → Surface Magnetic Flux Detection → Unloading