Off-line Standard Magnetization Detection Equipment

Product Application


Magnetization and detection equipment for electric motor rotors of new energy passenger vehicles.

This equipment is suitable for the magnetization and magnetic flux measurement of electric motor rotors of new energy passenger vehicles of various sizes.

It adopts the method of integral post-magnetization, which is safe and efficient. The magnetic flux detection coil is embedded in the magnetizing coil.


System Composition


Including magnetizing equipment, magnetizer, magnetizing coil, chiller, and magnetic flux meter (optional)


Product Features


1. Wide compatibility range of rotor

2. Simple operation and high automation length

3. Equipped with anti misoperation measures

4. Convenient changeover+changeover car (optional)

5. Support dual-mode switching (manual+robot/robotic arm)

6. Communication with the magnetizing power supply, real-time monitoring of equipment status

7. It can embed magnetic flux detection and integrate magnetization and magnetic flux


Technical Specifications


Project

Technical Specifications

Remarks

input power

AC220V±5% 50/60Hz


input current

< 20A


rated power

< 5KW


Equipment noise

≤ 75dB

Excluding instant magnetization

beat

Equipment action ≤ 30s; coil cooling ≤ 60s

Excluding loading and unloading materials

Device dimensions

Approximately 1100 x 1160 x 2350mm in length, width, and height


Size of electrical cabinet

Approximately 900 x 500 x 1700mm in length, width, and height


changeover time

≤ 20min

Fixture+coil (quick plug)


Usage Environment


1

Environmental temperature: 0 ℃~40 ℃;

2

Environmental humidity<80% (no condensation allowed);

3

Factory height (column top height): 3.5m;

4

Ground load:>2 tons/square meter;

5

Dimensions of the transportation door for factory equipment: width 1500 x height 2500mm;

6

Gas source: pressure 0.4-0.6Mpa, flow rate 0.3m3/ min;

7

No dust, no oil fumes, no salt, no dripping water;

8

Avoid direct sunlight exposure;

9

No flammable or corrosive liquids or gases;

10

No impact or high-frequency vibration;

11

Location of use: Workshop open environment.



Action Process


 Loading  Pressing Down  Magnetizing  Lifting Up   Magnetic Flux Detection  Unloading 


Online Consultation

Message Waiting for a visit Free customization