In line standard magnetization testing equipment

Product Application


New energy passenger vehicle motor rotor magnetization and testing equipment

This device is suitable for various sizes New energy passenger vehicles motor rotor Magnetization and magnetic flux measurement.

Adopting the overall post magnetization method, it is safe and efficient, and the magnetic flux detection coil can be embedded inside the magnetization coil.



System Composition


Including magnetizing equipment, magnetizing power supply, magnetizing coil, chiller, and magnetic flux meter (optional)


Product Features


1.  Wide compatibility range of rotor

2.  Simple operation, high automation length

3.  Capable of preventing misoperation

4.  Easy to change models + Replacement car (optional)

5.  The assembly line passes through the equipment, and the incoming material method of the assembly line tray

6.  The magnetizing detection coil can be raised and lowered

7.  Communication with magnetizing power supply, real-time monitoring of equipment status

8.  Can embed magnetic flux detection and magnetization + Integrated magnetic flux



Technical Specifications


project

Technical Specifications

Remarks

input power

AC220V±5% 50/60Hz


input current

20A


rated power

5KW


Equipment noise

≤ 75dB

Excluding instant magnetization

Device dimensions

Approximately length, width, and height: 1050×1350×2200mm

Including electrical cabinet

Equipment weight

1000kg


changeover time

≤ 30min

workwear + coil


Usage environment


one

Ambient temperature 0℃~40℃;

two

ambient humidity < 80% (no condensation allowed);

three

Factory height (column top height): 3.5m;

four

Ground load:> 2 tons/square meter;

five

Size of transportation door for factory equipment: width 1500 x 2500mm high;

six

Gas source: Air pressure 0.4~0.6Mpa , Flow rate of 0.3m 3/ min;

seven

No dust, no oil fumes, no salt, no dripping water;

eight

Avoid direct sunlight exposure ;

nine

No flammable or corrosive liquids or gases;

ten

No impact or high-frequency vibration;

eleven

Usage location: Workshop open environment.


action process


image.png

Online Consultation

Message Waiting for a visit Free customization